HCFCs
Genetron® HP80 (R-402A)
An interim replacement for retrofitting low- and medium-temperature commercial refrigeration systems. For low- and medium-temperature retrofits.
Overview
An interim replacement for retrofitting low- and medium-temperature commercial refrigeration systems. For low- and medium-temperature retrofits.Search SDS Number in SDS Finder - 09892
Specifications
Others
- Typical Lubricant
- AB
- Refrigerant Class
- HCFC
- Refrigerant Type
- Blend
- Linear Formula
- CHClF2, CF3CHF2, C3H8
- Chemical Name
- Chlorodifluoromethane, Pentafluoroethane, Propane
- ASHRAE Number
- R-402A
- Substitutes
- R-502
- Application
- Commercial Refrigeration
- Replaces
- R-502
- Glide
- Low
- Brand
- Genetron®
- Saturated Liquid Density
- 70 lb/ft3 at 86 °F
- Specific Heat of Liquid
- 0.34 Btu/lb at 86 °F
- Specific Heat of Vapor
- 0.16 Btu/lb at 86 °F and 1 Atm, at Cp
- Critical Pressure
- 611.97 psia
- Molecular Weight
- 101.6 lbm/lbmol
- Critical Temperature
- 168.47 °F (ASTM D-1321)
- Boiling Point/Range
- -56.1 °F at 1 Atm
- Freezing Point
- -153 °F at 1 Atm
- Ozone Depletion Potential
- 0.019
- Global Warming Potential
- 2788
- Flammable Range
- None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
- ASHRAE Safety Classification
- A1
Others
- Typical Lubricant
- AB
- Refrigerant Class
- HCFC
- Refrigerant Type
- Blend
- Linear Formula
- CHClF2, CF3CHF2, C3H8
- Chemical Name
- Chlorodifluoromethane, Pentafluoroethane, Propane
- ASHRAE Number
- R-402A
- Substitutes
- R-502
- Application
- Commercial Refrigeration
- Replaces
- R-502
- Glide
- Low
- Brand
- Genetron®
- Saturated Liquid Density
- 70 lb/ft3 at 86 °F
- Specific Heat of Liquid
- 0.34 Btu/lb at 86 °F
- Specific Heat of Vapor
- 0.16 Btu/lb at 86 °F and 1 Atm, at Cp
- Critical Pressure
- 611.97 psia
- Molecular Weight
- 101.6 lbm/lbmol
- Critical Temperature
- 168.47 °F (ASTM D-1321)
- Boiling Point/Range
- -56.1 °F at 1 Atm
- Freezing Point
- -153 °F at 1 Atm
- Ozone Depletion Potential
- 0.019
- Global Warming Potential
- 2788
- Flammable Range
- None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
- ASHRAE Safety Classification
- A1
- Typical Lubricant : AB
- Refrigerant Class : HCFC
- Refrigerant Type : Blend
- Linear Formula : CHClF2, CF3CHF2, C3H8
- Chemical Name : Chlorodifluoromethane, Pentafluoroethane, Propane
- ASHRAE Number : R-402A
- Substitutes : R-502
- Application : Commercial Refrigeration
- Replaces : R-502
- Glide : Low
- Brand : Genetron®
- Saturated Liquid Density : 70 lb/ft3 at 86 °F
- Specific Heat of Liquid : 0.34 Btu/lb at 86 °F
- Specific Heat of Vapor : 0.16 Btu/lb at 86 °F and 1 Atm, at Cp
- Critical Pressure : 611.97 psia
- Molecular Weight : 101.6 lbm/lbmol
- Critical Temperature : 168.47 °F (ASTM D-1321)
- Boiling Point/Range : -56.1 °F at 1 Atm
- Freezing Point : -153 °F at 1 Atm
- Ozone Depletion Potential : 0.019
- Global Warming Potential : 2788
- Flammable Range : None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
- ASHRAE Safety Classification : A1
Others
Name
Description
File Size
Date
Size
Solstice® N40, Solstice N13 pressure-temperature charts
application/pdf 404.2 KB
2/27/2023
404.2 KB
Name
Description
File Size
Date
Size
Solstice® N40, Solstice N13 pressure-temperature charts
application/pdf 404.2 KB
2/27/2023
404.2 KB
Name
Description
File Size
Date
Size
Solstice® N40, Solstice N13 pressure-temperature charts
404.2 KB
2/27/2023