HCFCs
Genetron® 409A (R-409A)
An interim replacement for R-12 in refrigeration systems. For low- and medium-temperature retrofits.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Others
- Typical Lubricant
- Alkylbenzene
- Refrigerant Class
- HCFC
- Refrigerant Type
- Blend
- Linear Formula
- CHClF2, CHClFCF3, CClF2CH3
- Chemical Name
- Chlorodifluoromethane, Chlorotetrafluoroethane, Chlorodifluoroethane
- ASHRAE Number
- R-409A
- Substitutes
- CFC-12
- Application
- Commercial Refrigeration
- Contains
- HCFC-22 (60%), HCFC-124 (25%), HCFC-142b (15%)
- Glide
- High
- Brand
- Genetron®
- Saturated Liquid Density
- 74.6 lb/ft3 at 86 °F
- Specific Heat of Liquid
- 0.3 Btu/lb at 86 °F
- Specific Heat of Vapor
- 0.15 Btu/lb at 86 °F and 1 Atm, at Cp
- Critical Pressure
- 682.66 psia
- Molecular Weight
- 97.4 lbm/lbmol
- Critical Temperature
- 228.66 °F (ASTM D-1321)
- Boiling Point/Range
- -30 °F at 1 Atm
- Flammable Range
- None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
- ASHRAE Safety Classification
- A1
Others
- Typical Lubricant
- Alkylbenzene
- Refrigerant Class
- HCFC
- Refrigerant Type
- Blend
- Linear Formula
- CHClF2, CHClFCF3, CClF2CH3
- Chemical Name
- Chlorodifluoromethane, Chlorotetrafluoroethane, Chlorodifluoroethane
- ASHRAE Number
- R-409A
- Substitutes
- CFC-12
- Application
- Commercial Refrigeration
- Contains
- HCFC-22 (60%), HCFC-124 (25%), HCFC-142b (15%)
- Glide
- High
- Brand
- Genetron®
- Saturated Liquid Density
- 74.6 lb/ft3 at 86 °F
- Specific Heat of Liquid
- 0.3 Btu/lb at 86 °F
- Specific Heat of Vapor
- 0.15 Btu/lb at 86 °F and 1 Atm, at Cp
- Critical Pressure
- 682.66 psia
- Molecular Weight
- 97.4 lbm/lbmol
- Critical Temperature
- 228.66 °F (ASTM D-1321)
- Boiling Point/Range
- -30 °F at 1 Atm
- Flammable Range
- None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
- ASHRAE Safety Classification
- A1
- Typical Lubricant : Alkylbenzene
- Refrigerant Class : HCFC
- Refrigerant Type : Blend
- Linear Formula : CHClF2, CHClFCF3, CClF2CH3
- Chemical Name : Chlorodifluoromethane, Chlorotetrafluoroethane, Chlorodifluoroethane
- ASHRAE Number : R-409A
- Substitutes : CFC-12
- Application : Commercial Refrigeration
- Contains : HCFC-22 (60%), HCFC-124 (25%), HCFC-142b (15%)
- Glide : High
- Brand : Genetron®
- Saturated Liquid Density : 74.6 lb/ft3 at 86 °F
- Specific Heat of Liquid : 0.3 Btu/lb at 86 °F
- Specific Heat of Vapor : 0.15 Btu/lb at 86 °F and 1 Atm, at Cp
- Critical Pressure : 682.66 psia
- Molecular Weight : 97.4 lbm/lbmol
- Critical Temperature : 228.66 °F (ASTM D-1321)
- Boiling Point/Range : -30 °F at 1 Atm
- Flammable Range : None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
- ASHRAE Safety Classification : A1