HFCs
Genetron® 245fa (R-245fa)
A non-ozone depleting candidate replacement for R-11 in centrifugal chillers. For new equipment.
Others
- Typical Lubricant
- Synthetic (P)E, PVE, etc.)
- Refrigerant Class
- HFC
- HFC
- Refrigerant Type
- Single component fluid
- Linear Formula
- CF3CH2CHF2
- Chemical Name
- Pentafluoropropane
- ASHRAE Number
- R-245fa
- Substitutes
- CFC-11
- Application
- Commercial A/C
- Commercial Refrigeration
- Organic Rankine Cycle
- Replaces
- R-11
- Brand
- Genetron®
- Saturated Liquid Density
- 82.7 lb/ft3 at 86 °F
- Specific Heat of Liquid
- 0.32 Btu/lb at 86 °F
- Specific Heat of Vapor
- 0.2 Btu/lb at 86 °F and 1 Atm, at Cp
- Critical Pressure
- 527.94 psia
- Molecular Weight
- 134 lbm/lbmol
- Critical Temperature
- 309.29 °F (ASTM D-1321)
- Boiling Point/Range
- 58.8 °F at 1 Atm
- Freezing Point
- -160 °F at 1 Atm
- Flammable Range
- None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
- ASHRAE Safety Classification
- B1
Others
- Typical Lubricant
- Synthetic (P)E, PVE, etc.)
- Refrigerant Class
- HFC
- HFC
- Refrigerant Type
- Single component fluid
- Linear Formula
- CF3CH2CHF2
- Chemical Name
- Pentafluoropropane
- ASHRAE Number
- R-245fa
- Substitutes
- CFC-11
- Application
- Commercial A/C
- Commercial Refrigeration
- Organic Rankine Cycle
- Replaces
- R-11
- Brand
- Genetron®
- Saturated Liquid Density
- 82.7 lb/ft3 at 86 °F
- Specific Heat of Liquid
- 0.32 Btu/lb at 86 °F
- Specific Heat of Vapor
- 0.2 Btu/lb at 86 °F and 1 Atm, at Cp
- Critical Pressure
- 527.94 psia
- Molecular Weight
- 134 lbm/lbmol
- Critical Temperature
- 309.29 °F (ASTM D-1321)
- Boiling Point/Range
- 58.8 °F at 1 Atm
- Freezing Point
- -160 °F at 1 Atm
- Flammable Range
- None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
- ASHRAE Safety Classification
- B1
- Typical Lubricant : Synthetic (P)E, PVE, etc.)
- Refrigerant Class : HFC|HFC
- Refrigerant Type : Single component fluid
- Linear Formula : CF3CH2CHF2
- Chemical Name : Pentafluoropropane
- ASHRAE Number : R-245fa
- Substitutes : CFC-11
- Application : Commercial A/C|Commercial Refrigeration|Organic Rankine Cycle
- Replaces : R-11
- Brand : Genetron®
- Saturated Liquid Density : 82.7 lb/ft3 at 86 °F
- Specific Heat of Liquid : 0.32 Btu/lb at 86 °F
- Specific Heat of Vapor : 0.2 Btu/lb at 86 °F and 1 Atm, at Cp
- Critical Pressure : 527.94 psia
- Molecular Weight : 134 lbm/lbmol
- Critical Temperature : 309.29 °F (ASTM D-1321)
- Boiling Point/Range : 58.8 °F at 1 Atm
- Freezing Point : -160 °F at 1 Atm
- Flammable Range : None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
- ASHRAE Safety Classification : B1