Genetron® 245fa (R-245fa)

A non-ozone depleting candidate replacement for R-11 in centrifugal chillers. For new equipment.

Overview
A non-ozone depleting candidate replacement for R-11 in centrifugal chillers. For new equipment.Search SDS Number in SDS Finder - 09878
Specifications

Others

  • Typical Lubricant
    • Synthetic (P)E, PVE, etc.)
  • Refrigerant Class
    • HFC
    • HFC
  • Refrigerant Type
    • Single component fluid
  • Linear Formula
    • CF3CH2CHF2
  • Chemical Name
    • Pentafluoropropane
  • ASHRAE Number
    • R-245fa
  • Substitutes
    • CFC-11
  • Application
    • Commercial A/C
    • Commercial Refrigeration
    • Organic Rankine Cycle
  • Replaces
    • R-11
  • Brand
    • Genetron®
  • Saturated Liquid Density
    • 82.7 lb/ft3 at 86 °F
  • Specific Heat of Liquid
    • 0.32 Btu/lb at 86 °F
  • Specific Heat of Vapor
    • 0.2 Btu/lb at 86 °F and 1 Atm, at Cp
  • Critical Pressure
    • 527.94 psia
  • Molecular Weight
    • 134 lbm/lbmol
  • Critical Temperature
    • 309.29 °F (ASTM D-1321)
  • Boiling Point/Range
    • 58.8 °F at 1 Atm
  • Freezing Point
    • -160 °F at 1 Atm
  • Flammable Range
    • None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
  • ASHRAE Safety Classification
    • B1

Others

  • Typical Lubricant
    • Synthetic (P)E, PVE, etc.)
  • Refrigerant Class
    • HFC
    • HFC
  • Refrigerant Type
    • Single component fluid
  • Linear Formula
    • CF3CH2CHF2
  • Chemical Name
    • Pentafluoropropane
  • ASHRAE Number
    • R-245fa
  • Substitutes
    • CFC-11
  • Application
    • Commercial A/C
    • Commercial Refrigeration
    • Organic Rankine Cycle
  • Replaces
    • R-11
  • Brand
    • Genetron®
  • Saturated Liquid Density
    • 82.7 lb/ft3 at 86 °F
  • Specific Heat of Liquid
    • 0.32 Btu/lb at 86 °F
  • Specific Heat of Vapor
    • 0.2 Btu/lb at 86 °F and 1 Atm, at Cp
  • Critical Pressure
    • 527.94 psia
  • Molecular Weight
    • 134 lbm/lbmol
  • Critical Temperature
    • 309.29 °F (ASTM D-1321)
  • Boiling Point/Range
    • 58.8 °F at 1 Atm
  • Freezing Point
    • -160 °F at 1 Atm
  • Flammable Range
    • None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
  • ASHRAE Safety Classification
    • B1
  • Typical Lubricant : Synthetic (P)E, PVE, etc.)
  • Refrigerant Class : HFC|HFC
  • Refrigerant Type : Single component fluid
  • Linear Formula : CF3CH2CHF2
  • Chemical Name : Pentafluoropropane
  • ASHRAE Number : R-245fa
  • Substitutes : CFC-11
  • Application : Commercial A/C|Commercial Refrigeration|Organic Rankine Cycle
  • Replaces : R-11
  • Brand : Genetron®
  • Saturated Liquid Density : 82.7 lb/ft3 at 86 °F
  • Specific Heat of Liquid : 0.32 Btu/lb at 86 °F
  • Specific Heat of Vapor : 0.2 Btu/lb at 86 °F and 1 Atm, at Cp
  • Critical Pressure : 527.94 psia
  • Molecular Weight : 134 lbm/lbmol
  • Critical Temperature : 309.29 °F (ASTM D-1321)
  • Boiling Point/Range : 58.8 °F at 1 Atm
  • Freezing Point : -160 °F at 1 Atm
  • Flammable Range : None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
  • ASHRAE Safety Classification : B1